Huawei RAID 2.0+ CKG: Same Disk Group or Different?

H13-611 By islever Editorial Last updated

RAID Technologies

Short answer

B The statement is false because a Huawei RAID 2.0+ CKG is built from chunks on different disks within the same disk group, not from different disk groups.

Question

In Huawei RAID 2.0+, a CKG is a logical storage unit comprising chunks from different disks in different disk groups, based on a RAID algorithm.
  1. True
  2. False Correct Answer

Key Takeaways

It tests whether you can separate the CKG (the RAID unit inside a disk group) from the disk group itself, and the main trap is accepting the true phrase “different disks” while missing “different disk groups.”

This H13-611 item tests the Huawei RAID 2.0+ chunk group (CKG) and its disk-group boundary. The statement is false (B): a CKG gathers chunks from different disks in the same disk group, not across different disk groups.

Common mistake: Choosing A because a CKG does span multiple disks is only half true. The chunks must come from disks in the same disk group, and the option’s “different disk groups” makes the statement false.

Expert Analysis

CKG belongs inside one disk group. In Huawei RAID 2.0+, a chunk group (CKG) is the RAID-formed unit that aggregates chunks selected from different physical disks, but those disks must be members of the same disk group. The disk group is the pool-level fault and administration boundary; the CKG is the RAID algorithm boundary within it. Therefore a CKG does not draw chunks from “different disk groups.”

Why option B is correct. The statement adds “different disk groups,” which crosses the wrong boundary. Option B (False) is correct: the described cross-disk-group composition is not a CKG. A true CKG is composed of chunks from different disks in the same disk group, so the qualifier “different disk groups” is the decisive error.

The trap the comment identifies. A learner comment explains that “ckg is formed from chunks from the same disk group.” That matches Huawei’s model and exposes why option A is tempting: the first half—chunks from different disks—is true, so the sentence looks right until the last phrase. The same-disk-group constraint is not incidental; it is what makes the CKG’s RAID protection and reconstruction scope predictable. If chunks were allowed across disk groups, the CKG would no longer align with the disk group’s failure and management domain.

How to hold the boundary. Remember: disk group = container; CKG = RAID group built inside that container from chunks on separate disks. Multiple CKGs can coexist in one disk group, and each CKG spans disks within it, not outside it. On exam day, read the boundary terms—same vs. different disk group—as the decisive qualifier.

Exam Strategy

For RAID 2.0+ questions, underline the container boundary nouns—disk, disk domain, disk group, CKG—before judging true or false. A statement can be correct about spanning disks and still be false because it crosses a disk-group boundary. Translate each option into a simple hierarchy: disk → disk group → CKG → LUN, then check whether the stated relationship moves sideways or downward. This technique also catches traps about hot-spare domains, reconstruction scope and chunk placement.

Frequently Asked Questions

What is a CKG in Huawei RAID 2.0+?

A chunk group (CKG) is a RAID-formed logical unit made of chunks from different disks within one disk group; it is the RAID protection unit inside that disk group.

Can a CKG include chunks from multiple disk groups?

No. Huawei RAID 2.0+ confines a CKG to chunks on different disks in the same disk group, so a cross-disk-group CKG is not valid.

Why is the statement in this question false?

It says the CKG uses chunks from different disk groups. The valid boundary is different disks within the same disk group, so the extra cross-disk-group condition makes the statement false.

More H13-611 FAQ →

Community Votes

B
100%

100% of anonymous learners picked answer B. Votes are pick records left by other test-takers — they are not the verified answer.

Discussion 1 contributions

Compiled from public community threads and reader submissions, lightly edited for clarity. Handles and vote tallies are shown as recorded, and comments reflect the views of individual contributors.

From public community threads 1

  1. 10c5cfe 👍 1 Answered B
    ckg is formed from chunks from the same disk group.

Reader comments & corrections

No reader corrections yet — spotted an error or have a note? Share it below.

Log in to comment, report an error, or add a note about this question.

← Back to H13-611 Study Guide