Requirements for Switch Link Aggregation Interfaces

H12-811 By islever Editorial Last updated

Ethernet Link Aggregation

Short answer

ACD The physical interface rates, duplex modes, and quantities of interconnected switches must be the same when using link aggregation.

Question

When two switches are connected through link aggregation, what are the requirements for the
interfaces on the two switches? (Choose all that apply.)
  1. The physical interface rates of the interconnected switches are the same. Correct Answer
  2. The physical interface IDs of the interconnected switches are the same.
  3. The duplex modes of the physical interfaces on the interconnected switches are the same. Correct Answer
  4. The physical interface quantities of the interconnected switches are the same. Correct Answer
  5. The models of the optical modules used by the interconnected switches are the same.

Key Takeaways

Tests understanding that link aggregation requires symmetric configuration of speed, duplex, and member link count, while rejecting hardware-specific mismatches like SFP types.

This page explains the mandatory interface requirements for Ethernet Link Aggregation (Eth-Trunk), including speed, duplex mode, and member count consistency between switches.

Common mistake: Candidates often select Option E (same optical module model) because it seems physically necessary, but it is not a protocol requirement for link aggregation formation.

Expert Analysis

Link aggregation, specifically Ethernet Link Aggregation (Eth-Trunk), bundles multiple physical interfaces into a single logical link to increase bandwidth and provide redundancy. For this logical grouping to function correctly across both ends of the connection, specific parameters must be consistent on all member interfaces.

The most attractive but wrong answer often focuses on hardware specifics like optical modules (Option E) or interface IDs (Option B). While using identical SFP modules is good practice for interoperability, it is not a protocol requirement; different vendors can interoperate with compatible transceivers, and interface IDs are unique local identifiers that do not need to match across devices. Similarly, the quantity of interfaces (Option D) might seem like a trick, but in standard static or LACP-based aggregation, both sides must agree on the number of active member links to form a stable bundle; if one side has two links and the other expects three, the configuration will fail or drop traffic.

The critical requirements are speed and duplex mode. All member interfaces in an Eth-Trunk must operate at the same rate (Option A) to ensure uniform packet processing and hashing behavior. If speeds differ, the load-balancing algorithm cannot distribute frames evenly, leading to performance degradation or loop detection issues. Furthermore, duplex modes must match (Option C); mixing full-duplex and half-duplex creates collision domains and errors that break the logical link's integrity. Therefore, matching rates, duplex modes, and the agreed-upon number of member links are the non-negotiable constraints.

Exam Strategy

When analyzing link aggregation questions, immediately filter out hardware-specific options like SFP models or interface IDs unless explicitly stated as a vendor constraint. Focus on protocol-level consistency: speed, duplex, and VLAN membership. Remember that 'quantity' refers to the number of active member links in the bundle, which must be symmetrically configured on both ends to establish the logical channel.

Frequently Asked Questions

Do member interfaces in an Eth-Trunk need the same speed?

Yes, all member interfaces in a link aggregation group must have the same physical rate (e.g., all 1Gbps) to ensure proper load balancing and frame ordering.

Is it required to use the same SFP optical modules on both sides?

No, while using compatible modules is best practice, link aggregation does not strictly require identical optical module models as long as they are interoperable.

Why must the number of physical interfaces be the same?

Both switches must agree on the number of active member links to form a stable logical channel; mismatched counts prevent the Eth-Trunk from establishing correctly.

More H12-811 FAQ →

Community Votes

A
34%
C
33%
D
33%

34% of anonymous learners picked answer A. Votes are pick records left by other test-takers — they are not the verified answer.

Discussion 3 contributions

Compiled from public community threads and reader submissions, lightly edited for clarity. Handles and vote tallies are shown as recorded, and comments reflect the views of individual contributors.

From public community threads 3

  1. Fmoura17 👍 1
    Answer: A, C, and D A. Same physical interface rates ✅ — All member interfaces must have the same speed (e.g., all 1Gbps). C. Same duplex mode ✅ — All member interfaces must use the same duplex mode (e.g., all full-duplex). D. Same number of physical interfaces ✅ — Both sides must have the same number of member links in the Eth-Trunk.
  2. amiie00 👍 1
    I think A,C,D and E sfp module must be same type SR-SR, LR-LR
  3. Creyes1495 👍 1
    Pag. 468

Reader comments & corrections

No reader corrections yet — spotted an error or have a note? Share it below.

Log in to comment, report an error, or add a note about this question.