FCoE FC-Map Configuration to Prevent Cross-Fabric Talk

Answer Correct answer: D — The fcoe fcmap command assigns an FC-Map that identifies the fabric and discards MAC addresses not part of the current fabric while QoS is preserved.

An engineer implements an environment with multiple traffic types on a consolidated I/O link between Cisco Nexus 9000 Series Switch and MDS 9000 Series Switch. The configuration must meet these requirements: • The unified I/O link must support LAN and SAN traffic. • A single, multipurpose Ethernet transport must be used. • The configuration must discard MAC addresses that are not part of the current fabric. • The QoS markings must be preserved. Which configuration set meets the requirements?

  1. MDS-A(config)# interface fcip4 -
  2. N9K-2(config)# interface Eth2 -
  3. MDS-B(config)# interface fc3 -
  4. N9K-1(config)# fcoe fcmap 0e.fc.1d Correct Answer

Community Votes

D
67%
B
33%

67% of anonymous learners picked answer D. Votes are pick records left by other test-takers — they are not the verified answer.

Community Insight

Configuring fcoe fcmap makes the switch discard MAC addresses not part of the current fabric; this is the FCoE fabric-isolation mechanism and works with the existing network-qos class for QoS.

On a converged Nexus link, fcoe fcmap sets the FC-Map that identifies the fabric and discards FCoE frames from foreign fabrics, preventing cross-fabric data corruption while preserving QoS.

Pointing at an fcip interface, a plain Ethernet interface, or a native MDS fc interface instead of the Nexus unified-link fcoe fcmap setting that performs fabric segregation.

Community Discussion (6 comments)

bizzar7774 👍 1 Selected: D
You can prevent data corruption due to cross-fabric talk by configuring an FC-Map that identifies the Fibre Channel fabric for this Cisco Nexus device. When the FC-Map is configured, the switch discards the MAC addresses that are not part of the current fabric. ( https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/san_switching/configuration/guide/b-cisco-nexus-9000-nx-os-san-switching-configuration-guide-933/m-n9000-san-s-enabling-feature-fcoe.html )
Gopz28 👍 1 Selected: B
An interface has to be trunk and qos marking is perserved with Auto qos hence answer is B
asd248402 👍 1 Selected: D
fcmap is neeed for segragation
udo2020 👍 1
A must be wrong because it is for SPAN sessions. B and C are wrong so it should be D!
crooks_1988 👍 1
I agree with D, also auto-qos command does not exist on MDS 9000 CLI reference guide
Arch_Angel 👍 3
Answer is D Configuring the FC-Map You can prevent data corruption due to cross-fabric talk by configuring an FC-Map that identifies the Fibre Channel fabric for this switch. When the FC-Map is configured, the switch discards the MAC addresses that are not part of the current fabric.

Comments & Corrections

No comments yet — spotted an error or have a note? Share it below.

Log in to comment, report an error, or add a note about this question.

Submitted for moderation before publishing. Keep it helpful and respectful.

Expert Analysis

Why the Answer Is Correct

On a converged Nexus 9000 link carrying both LAN and SAN, configuring fcoe fcmap <value> sets the global FC-Map that identifies the Fibre Channel fabric for that switch. When the FC-Map is configured, the switch discards FCoE frames whose MAC addresses are not part of the current fabric, preventing cross-fabric data corruption. QoS markings on the Ethernet transport are preserved because FCoE uses the existing network-qos class.

Why the Other Options Are Wrong

A. An fcip interface is for FCIP tunneling over IP, unrelated to fabric isolation on a unified link. B. A plain Ethernet interface (Eth2) does not enforce FC-Map-based fabric segregation. C. An fc interface on the MDS is a native Fibre Channel port, not the FCoE unified-link FC-Map setting.

Community Comment Notes

Votes D 67 / B 33. Arch_Angel (3 likes) and bizzar7774 quote the NX-OS SAN Switching Guide: the FC-Map "discards the MAC addresses that are not part of the current fabric." Gopz28's B answer is refuted because auto-qos alone does not perform fabric segregation.

Official Reference

Related Analysis

← Back to 350-601 Study Guide