Which RAID Level Uses Double Parity?
Short answer
D RAID 6 offers double parity, allowing the array to survive the simultaneous failure of two hard drives.
Question
Key Takeaways
The main trap is confusing RAID 5's single parity with RAID 6's double parity; remember that only RAID 6 supports dual-drive failure tolerance among standard levels.
Identify the RAID type that implements double parity for enhanced fault tolerance in infrastructure blueprints.
Common mistake: Candidates often select RAID 5 because it is the most common enterprise RAID level using parity. However, RAID 5 only has single parity and cannot tolerate two simultaneous failures, making it incorrect for a double-parity requirement.
Expert Analysis
The question asks to identify the RAID level that utilizes double parity. This is a fundamental hardware storage concept tested in CompTIA A+.
RAID 6 (Option D) is defined by its use of two independent parity blocks, often referred to as double parity. This architecture allows the array to withstand the simultaneous failure of up to two drives without data loss. The comment provided aligns with this technical definition, noting that RAID 6 can tolerate two drive failures.
RAID 0 (Option A) provides striping only, with no redundancy or parity. It offers performance but zero fault tolerance.
RAID 1 (Option B) uses mirroring, creating an exact copy of data on two drives. While it provides high redundancy, it does not use parity bits; it duplicates entire volumes.
RAID 5 (Option C) is a common distractor because it uses parity for fault tolerance. However, it employs only single distributed parity. Consequently, RAID 5 can only tolerate the failure of one drive. If a second drive fails before the first is rebuilt, data is lost. Therefore, it does not meet the "double parity" requirement.
The key distinction here is between single-parity solutions (RAID 5) and double-parity solutions (RAID 6). When a scenario specifically mentions tolerating multiple drive failures or requiring double parity, RAID 6 is the correct choice.
Exam Strategy
When troubleshooting or designing storage, always check the required fault tolerance. If the scenario specifies 'double parity' or 'two drive failures', immediately select RAID 6. Avoid RAID 5 unless single drive failure tolerance is specified, as it lacks the extra parity block.
Frequently Asked Questions
What is the minimum number of drives required for RAID 6?
Can RAID 5 be used if two drives fail?
Community Votes
100% of anonymous learners picked answer D. Votes are pick records left by other test-takers — they are not the verified answer.
Discussion 1 contributions
Compiled from public community threads and reader submissions, lightly edited for clarity. Handles and vote tallies are shown as recorded, and comments reflect the views of individual contributors.
From public community threads 1
-
Afie 👍 1 Answered DRAID 6 uses double parity, which means it can tolerate the failure of two drives without losing data
Reader comments & corrections
No reader corrections yet — spotted an error or have a note? Share it below.
Related Analysis
Practice All 220-1201 Questions
Access 105 questions with complete answers and detailed explanations.
View Full 220-1201 Practice Test →