VMware
Advanced VMware Cloud Foundation 9.0 Support (3V0-13.26) practice questions
- Questions
- 43
- Exam length
- 135 min
- Passing score
- 300
- Instant feedback per question
- Explanation for every option
- Free, no signup
Exam overview 3V0-13.26
Slow virtual machines in a workload domain, a vSAN disk group that will not claim, a VKS namespace that cannot reach its registry — none of these arrive labelled with the component at fault. 3V0-13.26, the Advanced VMware Cloud Foundation 9.0 Support exam, tests the ability to work from symptoms to a defensible root cause across the whole VCF stack. Passing leads to the VMware Certified Advanced Professional – VMware Cloud Foundation Support credential (VCAP-VCF Support), delivered by Broadcom through Pearson VUE, with 60 items in 135 minutes and a 300 pass mark on the 100-500 scaled score.
The guide's minimally acceptable candidate can implement, operate, maintain and troubleshoot a multi-region or multi-organization VCF private cloud. Support engineers, private cloud administrators and infrastructure engineers who spend their time on incident resolution are the natural audience. Familiarity with vCenter, ESX, vSAN, NSX, VCF Identity Broker, VCF Automation, VCF Operations for Logs and Networks, and vSphere Kubernetes Service is assumed; the exam is about using that knowledge when a failure crosses component boundaries.
The blueprint is narrower than the technology list suggests. Sections 1 to 4 have no testable objectives, and all 30 published objectives sit in Section 5, Troubleshoot and Optimize. They cluster into storage monitoring and resolution, workload domain and component diagnostics, VCF Automation and Supervisor/VKS faults, VCF Operations infrastructure with logs and alerts, and NSX connectivity, ECMP, high availability and logical packet walks. The working method is consistent: identify the symptom, gather evidence, isolate the cause, select a resolution, then validate the fix, knowing when an issue belongs with the vendor instead.
The practice bank follows that sequence. An item may hand you a Cloud Proxy alert or a failed VKS upgrade and ask which evidence to collect before acting; the explanation then traces the decision and why the other options jump ahead of it. Timed practice makes the evidence-first reflex automatic, and a detailed explanation for every answer turns a wrong pick into a specific objective worth revisiting.
Sample questions 5 of 43 shown
-
Q1
Application owners report intermittent slowness on VMs in a VCF workload domain cluster. In VCF Operations, the engineer sees that several hosts in that cluster show sustained memory ballooning and compression, and a colleague proposes ordering two more hosts. Following the performance-management approach documented for VCF Operations, what should the engineer do FIRST?VCF Operations separates utilization (how busy a resource is) from contention (whether demand is going unmet). Ballooning and compression are contention indicators: the hypervisor is reclaiming guest memory because the host cannot satisfy the working sets. The documented performance-management workflow is to confirm contention against the KPIs of the affected object — the Cluster Contention dashboard surfaces ballooning, compression, swap and CPU ready breaches for the cluster and its hosts — and only then choose a remediation. Adding hosts (C) and raising reservations (D) are remediation actions taken after the bottleneck is confirmed, and utilization alone (A) can be high in a perfectly healthy cluster, so it does not distinguish a real problem from normal load. -
Q2
An engineer edits a VKS cluster to a newer compatible VKr, but the rolling update never starts. The cluster shows: SystemChecksSucceeded = False, reason NotSucceeded Message: MisconfiguredSoftwareChecks failed A third-party admission webhook was installed in the cluster last month. What should the engineer do FIRST?Before a VKS guest cluster rolls to a new Kubernetes version, the upgrade runs software compatibility checks inside the cluster; a failing third-party admission webhook makes those checks reportMisconfiguredSoftwareChecks, and the controller refuses to start the rollout because the new control plane could be unable to admit its own workloads. The correct first action is to remediate the offending webhook (fix its configuration, or remove/reinstall a version compatible with the target VKr) so the pre-update checks pass. The skip annotation (C) is an explicit bypass reserved for cases where the risk has been accepted — it leaves an incompatible webhook in place and is not the first step. Upgrading the Supervisor (B) does not change the guest cluster's webhook, and reverting the VKr (D) only restores the old version without resolving the blocker. -
Q3
After a maintenance window, the Summary tab of a VCF workload domain cluster shows Cluster Services health as Unhealthy, and DRS has stopped generating recommendations. An engineer browsing the Hosts and Clusters view reports that the cluster contains no vCLS VMs at all. What should the engineer do NEXT?vSphere Cluster Services (vCLS) VMs host the DRS agent that makes placement decisions; if they are absent or powered off, DRS cannot generate recommendations and Cluster Services reports Unhealthy. vCLS VMs live in a dedicated hiddenvCLSfolder, which is not shown in the Hosts and Clusters inventory — so the next step is to look in VMs and Templates, confirm whether the agents exist, and check their power state and any retirement/power-off messages. If they are missing or permanently powered off, they are redeployed from the cluster's vCLS configuration. Changing the DRS automation level (A), toggling admission control (B) or restarting vpxd (C) all treat symptoms without establishing whether the DRS agents are running. -
Q4
A Tier-1 gateway providing NAT runs active-standby on edge-01 (preferred) and edge-02. Edge-01 was rebooted for maintenance, and the Tier-1 SR on edge-02 became active. Edge-01 has returned with node status Up and all BFD sessions up. The Tier-1 SR on edge-01 is still standby an hour later. The Tier-1 failover mode was never changed from its default. Why has the active role not returned to edge-01?For a Tier-1 gateway with an Edge cluster selected, NSX offers two failover modes: Preemptive (a recovered preferred node preempts its peer and becomes active again) and Non-preemptive, which is the documented default. In non-preemptive mode the recovered preferred node checks whether its peer is currently active and, if so, stays standby rather than taking the active role back. Because the failover mode was never changed, the SR remains on edge-02 until an administrator either sets the gateway to preemptive or fails the SR back manually. Standby relocation (A) only creates a replacement standby SR after an Edge node failure and does not explain a healthy node staying standby; active-active (C) is not a prerequisite for a Tier-1 to hold the active role; and (D) contradicts the stated node and BFD state. -
Q5
After a top-of-rack switch upgrade, vSAN Skyline Health for a VCF Workload Domain cluster shows several Unhealthy findings across the network, data and performance categories. The network team reports that the uplink misconfiguration introduced by the upgrade has now been corrected. Which two actions should the engineer take in Skyline Health NEXT? (Choose two.)Skyline Health runs its checks on a schedule, so after the underlay is repaired the engineer should trigger an on-demand retest of the affected checks rather than wait for the next cycle and continue working from stale results. Once the retest completes, the remaining findings should be triaged by dependency: network-level faults (MTU, uplink, TEP reachability) cascade into data, cluster and performance findings, so resolving the primary/root-cause findings first usually clears the dependent ones without separate remediation. Silencing findings (B) hides genuine problems, disabling Historical Health Service (E) destroys the trending data needed to prove recovery, and a proactive VM creation test (D) is a capacity/placement validation, not the next step after an underlay fix.
Reader reviews 21 ratings
-
The 3V0-13.26 practice questions were incredibly helpful. The detailed explanations made all the difference. Passed on my first attempt!
-
Passed 3V0-13.26 with flying colors thanks to these practice exams. The questions are harder than the real thing, which is exactly what you want.
-
The 3V0-13.26 explanations are where this really stands out. Not just which answer is right but WHY the others are wrong.
-
This 3V0-13.26 practice test is no joke — questions are challenging but fair. If you can pass these, you’ll pass the real exam.
-
Comprehensive coverage for 3V0-13.26. Every domain is represented and the question difficulty ramps up nicely.
-
Solid VMware prep material. The 3V0-13.26 questions are well-written and the answer rationales are thorough.
Frequently asked questions
Why does this exam have only one testable section?
Because Broadcom split the three role-based VCAP papers by responsibility. The Support blueprint puts all 30 testable objectives in Section 5, Troubleshoot and Optimize, leaving Sections 1 to 4 with none. They still supply context for recognising abnormal behaviour, but no marks go to design or installation theory. Direct your study time at the troubleshooting objectives.
What workflow do the troubleshooting scenarios follow?
Identify symptoms, gather evidence, isolate the cause, select a resolution, then validate the fix. That order is the paper's backbone because a fix chosen too early treats a symptom, not the cause. Items give an alert, a log entry or a performance curve and ask which step comes next; explanations show why jumping to remediation costs the mark.
Which tools come up for vSAN and storage faults?
Both vSAN-native health, capacity and performance data and the VCF tools that surface it, including VCF Operations. Objectives 5.1 to 5.4 cover vSAN and supported non-vSAN storage, policy compliance, disk groups, network and capacity faults. The exam also checks whether you can tell a storage symptom from a compute or network cause before deciding where to look.
How are NSX routing problems presented?
As evidence to interpret, not commands to recite. The objectives cover choosing the right VCF or NSX tool, connectivity and routing faults, ECMP, high-availability simulations and logical packet walks. A scenario may give you a failed ping or missing route and ask which hop breaks the path, so following a packet across segments and gateways matters more than CLI syntax.
What does a support scenario look like in practice?
Usually a short incident description, one or two pieces of evidence and a choice of next actions — collect a support bundle, check a dependency, restart a service or escalate. The right option fits the current diagnostic stage. The question bank trains you to read evidence before acting, which is the habit the 60-item paper rewards.
Where do the answer explanations earn their keep?
In showing why the tempting answer is premature. An explanation that names a Cloud Proxy certificate problem behind an alert, or a trusted-CA error behind a failed container pull, gives you a diagnostic pattern to reuse on another component. Scores alone only say the scenario went wrong; the reasoning shows which link in the evidence-to-root-cause chain needs practice.