Fiber Link Offline After Upgrade: Transposed TX/RX?

N10-009 By islever Editorial Last updated

Short answer

A Because the visual fault locator confirms the fiber is physically intact and properly terminated, the one remaining offline link is most likely caused by transposed TX/RX strands, so swap the transmit and receive pairs.

Question

A network administrator upgrades the network infrastructure from copper wiring to fiber connections to increase throughput between network closets. After the upgrade, most of the new connections come online, but one of the connections still remains offline. During troubleshooting with a visual fault locator, the administrator verifies that the final connection was terminated properly. Which of the following is the most likely issue with the fiber connection?
  1. Transposed TX/RX Correct Answer
  2. Incorrect SFP
  3. Incompatible cable
  4. CRC errors

Key Takeaways

The question tests whether you can separate physical fiber continuity from duplex polarity and link signaling, with the trap being that a VFL pass does not prove TX and RX are correctly paired.

A fiber link that remains offline after a copper-to-fiber upgrade, despite a visual fault locator confirming proper termination, is most likely suffering from transposed TX/RX strands; the answer is A.

Common mistake: The common wrong choice is B (incorrect SFP), which can indeed stop a fiber link, but it is not the best fit when only one run fails and the VFL already confirms the termination; CRC errors (D) require a live link, and an incompatible cable (C) is less directly supported by the verified termination.

Expert Analysis

Physical continuity is not the same as a working duplex link A visual fault locator (VFL) injects visible light into a fiber to reveal breaks, severe bends, and bad terminations. It answers whether light can travel through the strand; it does not prove that the far end is connected to the correct receiver or that the link can negotiate. The administrator has already established that the final connection was terminated properly, so the fault is likely in how the two fibers in the duplex pair are mapped rather than in the glass itself.

Why transposed TX/RX fits the evidence Fiber duplex communication requires the transmit (TX) strand on one end to land on the receive (RX) strand at the other end. If the pair is reversed at a patch panel, connector, or outlet, light still passes through and a VFL still shows a healthy path, but the equipment receives nothing on its RX port, so the link stays down. That matches the scenario: most new connections came online, only one connection remains offline, and the physical termination checks out. A supplied explanation makes the same point about duplex transmission and swapping the strands.

Ruling out the other choices B, an incorrect SFP, is a real cause of a fiber link failing to come up, typically through a wavelength, reach, or media mismatch; however, it is less likely when only one otherwise identical connection fails and the VFL confirms the path. C, an incompatible cable, could also prevent a link because of core size or mode mismatch, but the question's emphasis on verified termination points to polarity. D, CRC errors, requires a link to be up and passing frames, so it cannot explain a connection that is offline. The most likely issue is A, transposed TX/RX.

Official Reference

https://www.comptia.org/certifications/network

This link opens the official vendor documentation in a new tab.

Exam Strategy

When a single fiber run stays down after an upgrade, split the diagnosis into physical continuity, polarity, and transceiver compatibility. Treat a VFL pass as proof of a continuous path, not proof of a usable link; next verify TX-to-RX orientation, then SFP wavelength and media pairing. Eliminate options that require an established link, such as CRC errors, before choosing a hardware mismatch.

Frequently Asked Questions

Why can a VFL show a good fiber path when the link is still offline?

A VFL only confirms continuity and visible termination quality. If TX and RX are swapped, or the transceiver pairing is wrong, light may still pass but the link cannot come up.

How should I fix a suspected transposed TX/RX fiber pair?

Check the patch-panel and connector labeling, then swap the transmit and receive strands at one end. Confirm that link lights and interface status change before replacing hardware.

Could an incorrect SFP cause a single fiber link to stay down?

Yes, an SFP with the wrong wavelength, reach, or media type can prevent a link. However, with one failed run and a VFL-verified termination, transposed TX/RX is the more likely first check.

More N10-009 FAQ →

Community Votes

A
100%

100% of anonymous learners picked answer A. Votes are pick records left by other test-takers — they are not the verified answer.

Discussion 1 contributions

Compiled from public community threads and reader submissions, lightly edited for clarity. Handles and vote tallies are shown as recorded, and comments reflect the views of individual contributors.

From public community threads 1

  1. ERB14 👍 1 Answered A
    Transposed TX/RX: Fiber connections require duplex transmission where the transmit (TX) strands on one end connect to the receive (RX) strands on the other end. If the TX and RX strands are swapped/transposed, light still passes through properly (which is why a Visual Fault Locator/VFL shows proper termination without breaks), but no connection/link can be established. Simply swapping the fiber strands at one connector solves the issue.

Reader comments & corrections

No reader corrections yet — spotted an error or have a note? Share it below.

Log in to comment, report an error, or add a note about this question.

Practice All N10-009 Questions

Access 100 questions with complete answers and detailed explanations.

View Full N10-009 Practice Test →

← Back to N10-009 Study Guide