PFC Working Principles: Which Statements Are False?

H12-811-V2.0 By islever Editorial Last updated

Data Center Network Basics

Short answer

AB The false PFC statements are A (pause only when the buffer is full) and B (resume only after the buffer is fully cleared); PFC instead pauses at the XOFF threshold and resumes at the lower XON threshold.

Question

On an intelligent computing data center network, network administrators deploy various intelligent lossless network technologies such as PFC to implement a high-speed and low-latency lossless network.
Which of the following statements are false about the working principles of PFC? (Choose all that apply.)
  1. After PFC is deployed, the receive end sends PFC packets to the transmit end when the buffer is full, requesting the transmit end to reduce the packet sending rate. Correct Answer
  2. After backpressure is triggered, the receive end sends PFC stop packets to the transmit end only after the buffer of the receive end is cleared. Correct Answer
  3. After PFC is deployed, the receive end sends PFC packets to the transmit end when the received traffic exceeds a certain buffer threshold, requesting the transmit end to reduce the packet sending rate.
  4. After backpressure is triggered, the receive end sends PFC stop packets to the transmit end as long as the buffer of the receive end decreases to a certain extent.

Key Takeaways

It tests the two-watermark PFC control loop; the main trap is treating PFC as a last-resort full-buffer or clear-buffer mechanism instead of a threshold-based pause/resume mechanism.

This H12-811-V2.0 page explains Priority Flow Control (PFC) in an intelligent computing data center and identifies the false statements as A and B, while C and D match the threshold-based pause/resume behavior.

Common mistake: A common wrong selection is to mark D false because it mentions a buffer decrease; in context, D describes the resume side of PFC, where the receiver sends the control frame that ends the pause after buffer usage falls to the lower watermark.

Expert Analysis

PFC starts at the receiver buffer, not at a full-buffer condition. When a packet of a given priority arrives at the receive end, it enters a per-priority ingress buffer. PFC monitors that buffer against an XOFF watermark. Once usage crosses that watermark, the receiver sends a PFC pause frame for that priority to the transmitter. The transmitter pauses only that priority, while other priorities continue. This is the step where option A fails: waiting until the buffer is full is too late and is not the PFC trigger.

The pause is released at a lower watermark. While the sender is paused, the receiver continues draining the buffer. When usage falls to the lower XON/resume watermark, the receiver sends the control frame that ends the pause. It does not need to wait until the buffer is completely cleared. That makes option B false: “only after the buffer is cleared” describes a drain-to-empty condition, not the actual PFC resume trigger. Option D describes the resume side correctly: after backpressure is active, the receiver sends the stop-pause/control frame once the buffer decreases to the configured extent.

Option C is the accurate XOFF description. It says the receive end sends PFC packets when received traffic exceeds a certain buffer threshold, requesting the transmit end to reduce its sending rate. That matches the watermark-driven PFC pause trigger, so C is true. In exam wording, PFC pause is often summarized as asking the sender to reduce or stop sending traffic of that priority; the key detail is that the request is threshold-based, not full-buffer-based.

Verdict: The false statements are A and B. A wrongly places the pause trigger at a full buffer, and B wrongly delays resume until the buffer is completely cleared. C and D align with the threshold-based XOFF and XON behavior of PFC.

Exam Strategy

For PFC questions, separate the XOFF trigger from the XON trigger before reading the options. XOFF is sent when buffer usage crosses the upper watermark, not when the buffer is full; XON is sent when usage falls below the lower watermark, not when the buffer is empty. If an option says “full” or “completely cleared,” treat it as a likely false statement, then verify whether the option is describing pause or resume.

Frequently Asked Questions

Does PFC wait until the receive buffer is full before sending a pause frame?

No. PFC sends an XOFF pause frame when the per-priority buffer usage crosses a configured threshold, leaving headroom before the buffer is actually full.

When does the receiver send a PFC resume frame?

When receive buffer usage falls below the lower XON threshold, not only after the buffer is completely cleared; this resumes the paused priority.

Why is option D not one of the false statements?

D describes the resume side of PFC: after backpressure starts, the receiver sends the control frame that stops the pause once the buffer drops to the configured lower extent.

More H12-811-V2.0 FAQ →

Community Votes

B
50%
C
50%

50% of anonymous learners picked answer B. Votes are pick records left by other test-takers — they are not the verified answer.

Discussion 1 contributions

Compiled from public community threads and reader submissions, lightly edited for clarity. Handles and vote tallies are shown as recorded, and comments reflect the views of individual contributors.

From public community threads 1

  1. 1b20e93 👍 1
    A.(Incorrecto) Si esta lleno ya pierde paquetes. D. (Incorrecto) Si el buffer disminuye no se debería enviar paradas.

Reader comments & corrections

No reader corrections yet — spotted an error or have a note? Share it below.

Log in to comment, report an error, or add a note about this question.

← Back to H12-811-V2.0 Study Guide