Hyperflex External SAN Connectivity for Microsoft Clustering

Evaluate storage deployment options for traditional and high-performance networks
Answer Correct answer: C — Raw Device Mapping must be used to connect the Hyperflex infrastructure to the external SAN fiber channel array for Microsoft clustering.

A network engineer is designing a Cisco Hyperflex infrastructure. The infrastructure will be connected to an external SAN fiber channel array and must support Microsoft clustering. Which storage connectivity method must be used to meet these requirements?

  1. Fibre Channel over Ethernet
  2. Internet Small Computer Systems Interface
  3. raw device mapping Correct Answer
  4. server message block

Community Votes

C
75%
A
25%

75% of anonymous learners picked answer C. Votes are pick records left by other test-takers — they are not the verified answer.

Community Insight

The question tests the specific integration mechanism between HCI and legacy shared storage, where the common trap is confusing general network protocols like FCoE with the virtualization-level mapping technique.

This page clarifies that Raw Device Mapping (RDM) is the required storage connectivity method for Cisco HyperFlex when integrating with an external Fibre Channel SAN to support Microsoft clustering workloads.

Many learners select Fibre Channel over Ethernet (FCoE) because it connects Ethernet networks to FC arrays, but FCoE is a transport protocol, not the VM-level connectivity method required for clustering in this context.

Community Discussion (4 comments)

CoAsT_x 👍 1 Selected: C
Answer is C Cisco Press - Hyperconverged Infrastructure Data Centers: Demystifying HCI. Chapter 9. Cisco HyperFlex HyperFlex Integration with External Storage Examples of some applications where HX integrates with legacy infrastructure include Boot and run VMs that are stored on the legacy SAN. Use the SAN for storage backup. Migrate VMs and storage to the newer hyperconverged infrastructure. Use raw device mapping (RDM) from the fibre channel array for Microsoft clustering.
lurker8000 👍 1 Selected: A
A is correct
lurker8000 👍 1
I think this should be A. Yes, Fibre Channel over Ethernet (FCoE) can support Microsoft Clustering when using external storage solutions. In a clustered environment, shared storage is essential for failover and redundancy, and FCoE allows you to connect to Fibre Channel storage arrays over an Ethernet network.
Fcpoultry 👍 2 Selected: C
The appropriate option is RDM(Raw Device Mapping) for Microsoft external storage.

Comments & Corrections

No comments yet — spotted an error or have a note? Share it below.

Log in to comment, report an error, or add a note about this question.

Submitted for moderation before publishing. Keep it helpful and respectful.

Expert Analysis

Why the Answer Is Correct

Raw Device Mapping (RDM) is the correct answer because it allows a virtual machine to access a block device on the storage array directly. In the context of Cisco HyperFlex integrated with an external SAN, RDM is used to map the external LUNs to the VMs so they can participate in a Microsoft Failover Cluster. This ensures the cluster nodes see the storage as local, which is a strict requirement for Windows Server clustering.

Why the Other Options Are Wrong

Fibre Channel over Ethernet (FCoE) is a protocol that encapsulates FC frames within Ethernet, but it does not inherently provide the virtualization abstraction layer needed for the VMs to share the storage in a clustered configuration without additional software-defined storage components. Internet Small Computer Systems Interface (iSCSI) uses TCP/IP and is generally not the primary choice for high-performance FC SAN integration in this specific HCI scenario. Server Message Block (SMB) is a file-sharing protocol, whereas clustering typically requires block-level access for the database or system files.

Community Comment Notes

Community consensus strongly supports C, citing Cisco Press documentation on HyperFlex integration. One commenter noted that RDM is the appropriate option for Microsoft external storage specifically. Another user initially suggested FCoE but acknowledged the official guide points to RDM for these specific use cases like booting VMs from legacy SAN.

Exam Strategy

When dealing with HCI and external storage integration questions, distinguish between the transport protocol (like FCoE) and the virtualization mapping method (like RDM). For Microsoft clustering scenarios involving external shared storage, RDM is often the key term linking the VM to the SAN.

Frequently Asked Questions

Why not use FCoE for Hyperflex external storage?

FCoE is a transport protocol. While it enables connectivity, RDM is the specific virtualization technology used to map the external LUNs to the VMs for clustering awareness.

Can iSCSI be used for Microsoft clustering in Hyperflex?

While technically possible in some setups, the question specifies an external SAN fiber channel array, making RDM via the FC path the intended architectural solution.