UCS IOM to Fabric Interconnect Storage Connectivity

Answer Correct answer: C — UCS: two-port PortChannel from each IOM to each fabric interconnect

An engineer must design the compute portion of a data center environment. The environment includes: • direct-attach Fibre Channel storage array with four 32 G Fibre Channel ports per controller • Cisco UCS B-series servers equipped with Cisco UCS IOM 2408 Fabric Extenders • Cisco 6454 Fabric Interconnects The fabric interconnects connect to the LAN via 100G ports, the SAN via 32 G Fibre Channel ports, and the IOM 2408 via 10 G ports. Which storage connectivity strategy must the engineer choose?

  1. UCS: Qty four 802.1q trunks from each IOM to each fabric interconnect
  2. UCS: four-port back-to-back PortChannel between IOM and fabric interconnect
  3. UCS: two-port PortChannel from each IOM to each fabric interconnect Correct Answer
  4. UCS: four-port PortChannel from each IOM to each fabric interconnect

Community Votes

C
100%

100% of anonymous learners picked answer C. Votes are pick records left by other test-takers — they are not the verified answer.

Community Insight

The common trap is assuming that SAN port-channeling works with all storage arrays; however, direct-attach arrays typically lack this support, necessitating a specific link count.

This question evaluates the correct cabling strategy for connecting Cisco UCS IOM 2408 Fabric Extenders to Cisco 6454 Fabric Interconnects in a direct-attach Fibre Channel storage environment.

Option B (four-port back-to-back) or D (four-port PortChannel) are incorrect because they assume SAN port-channel support which direct-attach storage usually lacks, and back-to-back is not a standard interconnect method here.

Community Discussion (3 comments)

CoAsT_x 👍 1 Selected: C
Has to be C. Only MDS and NXOS support san-port-channel. Direct attach storage does not.
lurker8000 👍 1
Agree on C for this one.
Fcpoultry 👍 2 Selected: C
2 for IOM 4 for Fiber Channel

Comments & Corrections

No comments yet — spotted an error or have a note? Share it below.

Log in to comment, report an error, or add a note about this question.

Submitted for moderation before publishing. Keep it helpful and respectful.

Expert Analysis

Why the Answer Is Correct

The correct strategy is two-port PortChannel from each IOM to each fabric interconnect (Option C). The Cisco UCS IOM 2408 provides four 10 GbE ports. In a design where the storage is direct-attach Fibre Channel (not connected via MDS/NXOS switches), the IOM connects to the Fabric Interconnects using Ethernet uplinks. Since direct-attach storage arrays do not support SAN port-channeling (which requires FC switch support like on MDS/NXOS), you cannot bundle more links than necessary or assume multi-pathing protocols that rely on switch-side channeling. The standard best practice for redundancy and bandwidth in this specific 'direct-attach' context without FC switch involvement is to use two ports per connection (one to each FI) forming a PortChannel, leaving two ports available or unused depending on the exact model constraints, but critically, it avoids the unsupported SAN port-channel.

Why the Other Options Are Wrong

Option A suggests 802.1q trunks, which is a VLAN tagging concept, not a physical connectivity strategy for the IOM-FI link itself. Option B suggests a 'back-to-back' PortChannel, which is technically nonsensical in this topology as it implies connecting the IOM directly to another IOM or a non-existent peer without the FI. Option D suggests a four-port PortChannel; while physically possible if all ports were used, it doesn't provide the necessary cross-FI redundancy if the design implies connecting to both FIs, and more importantly, community consensus highlights that direct-attach scenarios often restrict the logical channeling capabilities compared to switched SAN environments.

Community Comment Notes

Commenters consistently agree on C. One user noted, 'Only MDS and NXOS support san-port-channel. Direct attach storage does not,' highlighting the key constraint. Another user succinctly stated, '2 for IOM 4 for Fiber Channel,' reinforcing the split between IOM uplink ports and FC controller ports.

Exam Strategy

Always distinguish between switched SAN (MDS/NXOS) and direct-attach storage when evaluating port-channel options. If direct-attach, SAN port-channeling is generally not supported, limiting your uplink strategy.

Frequently Asked Questions

Why can't we use a four-port PortChannel?

Direct-attach storage does not support SAN port-channeling. Using fewer ports (two) ensures proper redundancy across FIs without relying on unsupported FC switch features.

What is the role of the 32G FC ports?

The 32G FC ports on the Fabric Interconnects connect directly to the storage array controllers, handling the actual storage traffic, separate from the IOM uplinks.

More 300-610 FAQ →

Related Analysis

← Back to 300-610 Study Guide