RAID rebuild explains post-upgrade slowness and SMART errors
Short answer
C Allow the RAID array to finish rebuilding before measuring database performance or replacing the newly upgraded drive.
Question
Key Takeaways
This tests recognising rebuild-window contention in a RAID array; the trap is treating post-upgrade S.M.A.R.T. errors and latency spikes as evidence the new drive has failed.
On a 220-1201 database server question, a freshly upgraded RAID drive causing slow performance, longer read/write times and random S.M.A.R.T. errors signals an in-progress array rebuild, so the correct next step is C — let the rebuild finish.
Common mistake: Option D, replacing the faulty drive: the drive was just installed and the errors appeared only after the upgrade, so the S.M.A.R.T. warnings and elevated read/write times are transient rebuild activity, not media failure.
Expert Analysis
The governing principle
The deciding doctrine here is the RAID rebuild window. When a single member of a redundant array is swapped for a larger or newer drive, the controller must recalculate parity (or mirrored blocks) across the entire array before redundancy is restored. During that window the controller issues continuous background reads and writes, so every foreground request competes for the same spindles and queue depth. That contention is exactly what the question describes: degraded throughput plus an increase in read/write times on a freshly upgraded drive.
Mapping the scenario
The key is the sequence of events — the drive was upgraded, then symptoms appeared. A pre-existing hardware fault would have shown S.M.A.R.T. errors before the swap, not after. The random S.M.A.R.T. warnings reported by monitoring tools during a rebuild are commonly transient artifacts of the controller hammering the new member with verification I/O, not proof the media has failed. Option D therefore misreads cause as effect. Option A is unjustified: nothing indicates controller failure, and a controller swap would interrupt the array entirely. Option B treats a storage-layer bottleneck as an application-tuning problem; database optimization cannot fix saturated physical I/O.
Why C is correct
C is the correct answer: the administrator should allow the array to finish rebuilding and then re-measure. If performance and S.M.A.R.T. reporting normalise after rebuild completion, the investigation ends. Only if errors persist post-rebuild does drive replacement (D) become the next step — the rebuild-first rule keeps you from discarding a healthy new drive.
Comment corroboration
A community explanation agrees, noting that after a RAID member replacement "disk activity is very high" and "read/write performance is slower than normal," with monitoring tools surfacing temporary errors while the controller rewrites the array.
Official Reference
https://www.compTIA.org/en-us/certifications/a
This link opens the official vendor documentation in a new tab.
Exam Strategy
Anchor on the timeline in the scenario: symptoms that begin immediately after a hardware change usually reflect that change's expected side effects rather than a new fault. For storage questions, ask whether the array is still rebuilding — degraded throughput, high disk activity and transient S.M.A.R.T. warnings are textbook rebuild behaviour. Eliminate replacement and controller-swap options until the post-rebuild state is verified, then re-test.
Frequently Asked Questions
Why do S.M.A.R.T. errors appear during a RAID rebuild?
When should I replace a drive showing S.M.A.R.T. errors?
Does replacing a RAID drive improve database performance immediately?
Community Votes
100% of anonymous learners picked answer C. Votes are pick records left by other test-takers — they are not the verified answer.
Discussion 1 contributions
Compiled from public community threads and reader submissions, lightly edited for clarity. Handles and vote tallies are shown as recorded, and comments reflect the views of individual contributors.
From public community threads 1
-
Afie 👍 1 Answered CA hard drive was recently upgraded in a database server. Performance is slower than normal. Read/write times have increased. There are random S.M.A.R.T. errors. When a drive in a RAID array is replaced or upgraded, the RAID controller typically performs a rebuild operation. During the rebuild: Disk activity is very high. Read/write performance is slower than normal. Monitoring tools may report temporary warnings or degraded performance. Increased latency is expected until the rebuild completes.
Reader comments & corrections
No reader corrections yet — spotted an error or have a note? Share it below.
Related Analysis
Practice All 220-1201 Questions
Access 105 questions with complete answers and detailed explanations.
View Full 220-1201 Practice Test →