Handling SMART Failure Predictions in Redundant Drive Systems

220-1201 By islever Editorial Last updated

Given a scenario, troubleshoot drive and RAID issues Given a scenario, troubleshoot motherboards, RAM, CPUs, and power

Short answer

B Request a replacement unit to ensure the failing drive can be swapped and the redundant array restored when parts are available.

Question

A computer with two redundant drives is displaying an error:
SMART failure predicted: Drive 1
A technician notes that a spare drive is not available and the computer is currently functioning normally. Which of the following should the technician do next?
  1. Immediately remove the drive.
  2. Request a replacement unit. Correct Answer
  3. Rebuild the array.
  4. Restore the computer base image.

Key Takeaways

The question tests the ability to distinguish between a predicted failure and an actual failure, recognizing that you cannot rebuild an array without the necessary hardware on hand.

Learn how to respond to SMART failure warnings in systems with redundant drives. When no spare is available, requesting a replacement unit is the correct next step to maintain data integrity.

Common mistake: Technicians often choose to rebuild the array (C) because they focus on the redundancy aspect. However, rebuilding is impossible without a replacement drive, making 'requesting a replacement' the only feasible immediate action.

Expert Analysis

SMART Failure Prediction is a Proactive Alert

The core concept here is interpreting SMART (Self-Monitoring, Analysis and Reporting Technology) warnings. A "predicted failure" indicates that the drive has detected internal metrics suggesting imminent hardware degradation, but it is not yet failed. The system is still operational, which is critical.

Why Option C (Rebuild the array) is the Trap

Option C sounds like the most logical technical action because the scenario mentions "two redundant drives," implying a RAID configuration (likely RAID 1). In a healthy RAID 1 setup, if one drive fails, the array rebuilds automatically or manually using the surviving mirror. However, rebuilding requires a replacement drive to be present in the system to take over the data. Since the prompt explicitly states "a spare drive is not available," attempting to rebuild immediately is impossible or would result in an incomplete/unsafe operation without proper procedure. Furthermore, you cannot rebuild before you have the physical media to rebuild with. Therefore, jumping straight to rebuild ignores the logistical constraint provided.

Why Option B (Request a replacement unit) is Correct

Given that the computer is functioning normally and redundancy exists, the immediate risk of data loss is low. The priority is to secure the hardware needed to restore full redundancy before the first drive actually dies. Since no spare is on hand, the technician must acquire one. Requesting the replacement unit ensures the part arrives so the array can be rebuilt promptly once the failing drive is swapped. This aligns with best practices for proactive maintenance: acknowledge the warning, procure the part, then execute the repair.

Other Options

  • A (Immediately remove the drive): Removing the drive while the system is running could cause a crash or data corruption if the OS expects both drives. It also leaves the system non-redundant unnecessarily.
  • D (Restore the computer base image): This is irrelevant to hardware failure and would waste time restoring software configurations instead of addressing the physical component issue.

Official Reference

https://www.smartmontools.org/wiki/Main_Page

This link opens the official vendor documentation in a new tab.

Exam Strategy

Always read the constraints carefully. If a scenario mentions 'redundancy' or 'RAID,' look for the presence of replacement hardware. If the hardware is missing, any option requiring its installation (like rebuilding) is incorrect. Prioritize procurement steps over execution steps when resources are unavailable.

Frequently Asked Questions

What does a SMART failure prediction mean?

It means the drive's internal monitoring system has detected attributes indicating it is likely to fail soon, even though it is still currently functional.

Can I continue using a drive with a SMART warning?

Yes, temporarily, especially if redundancy exists. However, you should plan to replace it immediately as it may fail unpredictably.

Why not just replace the drive without requesting a spare?

The scenario states no spare is available. You must procure the part before you can physically perform the replacement and rebuild.

Community Votes

B
100%

100% of anonymous learners picked answer B. Votes are pick records left by other test-takers — they are not the verified answer.

Discussion 1 contributions

Compiled from public community threads and reader submissions, lightly edited for clarity. Handles and vote tallies are shown as recorded, and comments reflect the views of individual contributors.

From public community threads 1

  1. Afie 👍 1 Answered B
    A SMART failure predicted warning means the drive is likely to fail soon, but it has not failed yet. Key clues: The system has two redundant drives (such as RAID 1). The computer is still functioning normally. No spare drive is available. The best next step is to request a replacement drive so the failing drive can be replaced as soon as possible.

Reader comments & corrections

No reader corrections yet — spotted an error or have a note? Share it below.

Log in to comment, report an error, or add a note about this question.

Practice All 220-1201 Questions

Access 105 questions with complete answers and detailed explanations.

View Full 220-1201 Practice Test →

← Back to 220-1201 Study Guide