Intermittent Fiber Connectivity: Interface Errors or Cable Fault?
[sampleXML/xmlfile-49_1.png] Refer to the exhibit. Shortly after SiteA was connected to SiteB over a new single-mode fiber path, users at SiteA report intermittent connectivity issues with applications hosted at SiteB. What is the cause of the intermittent connectivity issue?
Community Insight
The question tests whether you can read reliability and load counters to confirm a fault, and the trap is picking the physically 'plausible' cable or SFP fault instead of what the exhibit actually evidences.
This CCNA 200-301 troubleshooting item examines a new single-mode fiber link between SiteA and SiteB where SiteA users see intermittent connectivity, using interface counters (reliability, load, SFP type) to isolate the fault. The exhibit proves SiteA's interface reliability has dropped to 166/255 while load stays at 1/255 and the optics/cabling match, so incrementing interface errors is the documented cause.
Most learners choose D (wrong cable type) or C (wrong SFP at SiteA), reasoning that a bad fiber run is the real cause; however, the output shows single-mode cabling with matching long-reach (LR) optics on both ends, so the only item the exhibit supports is A, incrementing interface errors (reliability below 255/255).
Community Discussion (45 comments)
Comments & Corrections
No comments yet — spotted an error or have a note? Share it below.
Expert Analysis
Why the Answer Is Correct
SiteA's interface counters report reliability 166/255 instead of the healthy 255/255 seen at SiteB, and the reliability metric on Cisco IOS is derived from successful frame delivery versus received frames, so a value below 255 means input/output errors (CRC, giants, input errors) are accumulating on that link. Because the load counters remain 1/255, the errors are not traffic-driven, and the exhibit therefore documents incrementing interface errors as the condition producing the intermittent loss to SiteB. Option A is the only statement directly evidenced by the output.Why the Other Options Are Wrong
Option B is eliminated by txload and rxload of 1/255, which represent minimal utilization, so high usage causing high latency is contradicted by the counters. Option C fails because both ends of the link show the same long-reach single-mode optic, so an incorrect SFP media type at SiteA is not present in the exhibit. Option D, a wrong cable type, is a plausible real-world physical-layer cause but the exhibit confirms a single-mode fiber path paired with LR optics, so the output does not support it; as one commenter put it, "Error increase is not the cause of the issue is the consequence/result of the issue!!"Community Comment Notes
The comments split on exam semantics. Several voters, including Elidor and splashy, argue that since the exhibit is what the question tells you to use, A is the only defensible choice, with splashy noting "166/255 reliability is going down = errors increasing txload & rxload 1/255 which means low sent/transfer and received traffic = so definitely not high usage". Portcullis acknowledges preferring D personally but warns to "always use information from the exhibit", while RougePotatoe and VictorCisco object that errors are a symptom, not a root cause, and befa13c and 1Abel1 defend D by pointing to one-sided degradation consistent with a bad fiber run. On exam day, the exhibit-based, verifiable observation (A) is the safer selection.Exam Strategy
When the exhibit shows counters, answer with what the counters prove rather than a speculative root cause you cannot verify. Use reliability 255/255 versus 166/255 to spot errors, and use load values to quickly rule out congestion-based options like high usage.
Frequently Asked Questions
Why isn't a wrong fiber cable type the correct answer when errors suggest a physical fault?
The exhibit already confirms a single-mode fiber path with matching long-reach optics at both sites, so the cable/media options are disproven by the output; only the reliability counter shows an actual fault.
What does reliability 166/255 on a Cisco interface mean compared to 255/255?
Reliability is a 255-based scale where 255/255 means error-free delivery; a value like 166/255 indicates frames are being dropped or errored, typically from incrementing input or CRC errors.